Direct-acting relief valve - RDDALAN

Supplier:
User Library
Model Name:
Direct-acting relief valve - RDDALAN
Configuration Name:
Part Number:
RDDALAN
Quantity:
First Name:
Last Name:
Email:
Phone Number:
Company Name:
Address:
City:
State/Province:
Country:
Zip or Postal Code:
Comments:
Email me a copy:
   
Modified on: September 02,2026  
Rating: 
Downloads: 0
 
Comments: 
 
 

Do you have a better or corrected version of this model?
Post Alternate Version   (Login required)
Embed this 3D Model in your Blog

 
Report inappropriate content

Specifications
Supplier part number: RDDALAN
Name:Direct-acting relief valve - RDDALAN
Description:Direct-acting relief cartridges are normally closed, pressure-limiting valves used to protect hydraulic components from pressure transients. When the pressure at the inlet (port 1) reaches the valve setting, the valve starts to open to tank (port 2), throttling flow to limit the pressure rise. These valves are smooth and quiet, essentially zero leak, dirt tolerant, immune to silting and are very fast. All 2-port relief cartridges (except pilot reliefs) are physically and functionally interchangeable (same flow path, same cavity for a given frame size). Will accept maximum pressure at port 2; suitable for use in cross port relief circuits. The seals on the adjust screw are exposed to system pressure which means this valve can only be adjusted when the pressure is removed. The setting procedure is; check the setting, remove the pressure, adjust the valve, check the new setting. Valve is relatively insensitive to varying oil temperatures and oil borne contamination. Select a spring range where the desired relief setting is approximately mid-range to high between the minimum and maximum pressure to ensure maximum valve repeatability. Suitable for use in load holding applications. Back pressure on the tank port (port 2) is directly additive to the valve setting at a 1:1 ratio. Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals. Test pressure for each range is as follows: A range - 2000 psi (138 bar), B range - 1000 psi (69 bar), C range - 4000 psi (276 bar), D range - 800 psi (55 bar), E range - 400 psi (28 bar), S range - 150 psi (10 bar), W range - 3000 psi (207 bar). Reseat meets or exceeds 90% of crack pressure at test setting. Settings lower than the test pressure may result in lower reseat percentages. Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation t
   

 

Download the model according to the specified sizing parameters in either 3D or 2D format.
(Login required)
  Be the First to Rate this Part  (Login required)

Report Inappropriate Comment


Do you have a different version of this model? Post Alternate Version (Login required)